GreaseShield® GS1000-LL-F
Approvals
ASME A112.14.3-2000 Testing of Grease Interceptors, ASME A112.14.4-2001 Grease Removal Devices, CSA B481.0-2012 Testing of Grease Interceptors, CSA B481.1-2012 Testing and Rating of Grease Interceptors using Lard, CSA B481.5-2012 Testing and Rating of Grease Interceptors Equipped with a Grease Removal Device & PDI G 101. UL Approved (File No: E361705). Machinery Directive 2006/42/EC and EMC directive 2004/108/EC.
Flow Rates
Passive PDI =2GPM/7.571 L/m
Pro Active=1.5 L/S
Application
10 to 20 Grid Convection and Steam Combi Ovens and Rotisserie Chicken Ovens and sink not exceeding rated flows.
Functions & Features
- FilterShield
- Genie H2O Heater On Demand System -Supplied as standard (2509P01)
- 24 Volt PLC 4 Way - Controls both main and LL tank operation
- LL Tank Filter built in for LL Inlet - Ensure ovens are plumbed into the LL inlet, and sink(s) into the FilterShield inlet
- Solenoid Valve WRAS approved (or similar approval) Solenoid
- Anti-Flood Pump - To maintain normal water level + recalibration feature
- Anti-Flood Sensor included
Parts Supplied as Standard
- Vortex Flow Controller - Fitted as option on normal inlet.
- Running Trap – 54mm Running trap fitted on outlet as standard.
- FlexiPlumb:-54mm Running trap(0635D04-54), 54mm 90° bend(0635P02-54), 40mm 90° bend (0635P02-40) x2, 40mm straight (90635P01), 34mm 90°(0635P02-34)
- 40mm Blanking Cap (0635D10-40) x2
- Key (0509P86)
- Braided Hose For Hot Water (0214P01) x 2 as part of Genie H2O
- Plumbing Pack-see Note
Default Program
(V1.0 1000-LL)
Start 7.00 Am, Stop 02.30 Am. FOG roller pulsing 5 mins On 5 mins off. Anti-Flood and Recalibration cycle, when water intake activated roller is inhibited. Mains lead per country
Installation Kit
- Units must be at floor level or located on drop frame castored stands
- IP56 Socket
- Best Practice Management and Do’s and Don'ts, both laminated to be displayed on site
- Daily Maintenance Logbook (12 months)
- Sampling Point
- Spare filter basket
EU
- Voltage: 240 Volts
- Frequency: 50Hz
- Current: 0.6Amps
|
|
US
- Voltage: 120 Volts
- Frequency: 60Hz
- Current: 1.2Amps
|
|